FANUC Alarm SVGN-111 — Failed to touch fixture.

FANUC SVGN-111 (“Failed to touch fixture.”): The gun tip reached the master position without detecting the fixture (i.e. First check: Confirm that the zero position is correct, then confirm that a rigid fixture is between the tips during the second step of tip wear measurement.

Updated 2026-09-17 · LogrobotLM reference

Description

The gun tip reached the master position without detecting the fixture (i.e. tip wear plate) during the second step of tip wear measurement.

Remedy

Confirm that the zero position is correct, then confirm that a rigid fixture is between the tips during the second step of tip wear measurement.

Related codes