FANUC Alarm SYST-046 — SYSTEM Control Reliable/CE Mark config mismatch
FANUC SYST-046 (“SYSTEM Control Reliable/CE Mark config mismatch”): Either 1.Control Reliable or CE Mark hardware exists but the CR or CE Mark option has not been loaded,or 2.The Control Reliable/CE Mark option has been loaded but the hardware is not available. First check: If the Control Reliable/CE Mark option has not been loaded, load the Control Reliable/ CE Mark option.
Updated 2026-09-17 · LogrobotLM reference
Description
Either 1.Control Reliable or CE Mark hardware exists but the CR or CE Mark option has not been loaded,or 2.The Control Reliable/CE Mark option has been loaded but the hardware is not available.
Remedy
If the Control Reliable/CE Mark option has not been loaded, load the Control Reliable/ CE Mark option. If it has been loaded then this is a system without the Control Reliable/ CE Mark hardware and the system must be totally reloaded WITHOUT the Control Reliable/CE Mark option.
Related codes
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →