FANUC Alarm SYST-166 — WARN TP intermittent communication error
Warning- Hardware
- teach pendant
- Controllers
- R-30iA (this generation only)
- FANUC class
- WARN
FANUC SYST-166 (“WARN TP intermittent communication error”): Intermittent errors happened during the communication with the teach pendant. First check: Check that the teach pendant cable is working properly. Likely part: Teach pendant (Teach pendant).
Updated 2026-10-22 · LogrobotLM reference
Description
Intermittent errors happened during the communication with the teach pendant.
Remedy
Check that the teach pendant cable is working properly. Replace the cable if necessary. Check to determine if there is any source of electrical noise. Check that the teach pendant is working properly and replace the teach pendant if necessary.
Field diagnosis
Intermittent errors on the link with the teach pendant, without a stop.
What to check
- Source of electrical noise, condition of the teach pendant, replacement if necessary.
- Note: Precursor of SYST-165.
Part to check / replace
FANUC SYST-166 points to the hardware below — start here before ordering.
Tap a part for every code that points to it — and verify the exact variant for your controller before ordering.
Related codes
Same hardware involved