LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free →

FANUC Alarm SRVO-372 — OPEMG1 status abnormal

Error
Hardware
emergency stop and dual safety chains
Controllers
R-30iA / R-30iB
FANUC class
SERVO

FANUC SRVO-372 (“OPEMG1 status abnormal”): A chain alarm was detected with the emergency stop switch on the operator's panel. First check: 1. Replace the panel board. Likely part: Teach pendant (Teach pendant) +1 more.

Updated 2026-10-22 · LogrobotLM reference

Description

A chain alarm was detected with the emergency stop switch on the operator's panel.

Remedy

1. Replace the panel board. 2. Replace the teach pendant cable. 3. Replace the teach pendant. 4. Replace the emergency stop button on the operator's panel.

Field diagnosis

Chain alarm on the operator panel emergency stop button: one of the two button channels does not follow.

What to check

  • Replacement order: panel board or emergency stop board, teach pendant cable, teach pendant, then the button itself.
  • The teach pendant cable carries part of the chain, hence its place in the list.
  • Note: A button that "catches" halfway generates 372/373 intermittently.

Part to check / replace

FANUC SRVO-372 points to the hardware below — start here before ordering.

Tap a part for every code that points to it — and verify the exact variant for your controller before ordering.

Related codes

Same hardware involved

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →