LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free →

FANUC Alarm VISN-037 — WARN Vis_Proc. not Feature Find …

Manufacturer wording — WARN Vis_Proc. not Feature Find %d
The manual prints placeholders; your controller fills them in with the real group, axis or number.

FANUC VISN-037 (“WARN Vis_Proc. not Feature Find …”): You called the built-in routine WIN_GET_FF with a VIS_PROCESS which is not trained as a location tool. First check: Do not call WIN_GET_FF with this type of VIS_PROCESS.

Updated 2026-09-17 · LogrobotLM reference

Description

You called the built-in routine WIN_GET_FF with a VIS_PROCESS which is not trained as a location tool.

Remedy

Do not call WIN_GET_FF with this type of VIS_PROCESS. The value of "xxx" indicates the type of VIS_PROCESS you passed in: 20. Combine FF List Vision Process 21. Match List Vision Process 25. Found Feature Measurement Tool 26. Gauge Measurement Tool 27. Pixel Statistics Measurement Tool 29. Feature Find Location Tool, algorithm not specified

Related codes