KUKA Error 1214 — POWER FAILURE
ErrorDisplayed as KSS01214 on KRC4 / KRC5 controllers
KUKA 1214 (“POWER FAILURE”): The supply voltage for the controller cabinet has been switched off. First check: If there was no manual switch-off or failure of the power supply, check the mains voltage.
Updated 2026-09-09 · LogrobotLM reference
Cause
The supply voltage for the controller cabinet has been switched off. Collapse of the voltage of the power supply.
Effect
Path-maintaining stop. Calibration data retained in buffer memory. Data saved to the HDD hard disk. All active commands inhibited.
Troubleshooting
If there was no manual switch-off or failure of the power supply, check the mains voltage.
Related codes
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →