LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free →

KUKA Error 2112 — IDENTIFIER NOT DECLARED

Displayed as KSS02112 on KRC4 / KRC5 controllers

KUKA 2112 (“IDENTIFIER NOT DECLARED”): In the subprogram or function, no data type has been assigned to the identifier (this is the name of the transfer parameter). First check: Modify the program accordingly.

Updated 2026-09-09 · LogrobotLM reference

Cause

In the subprogram or function, no data type has been assigned to the identifier (this is the name of the transfer parameter).

Effect

The program is not executable.

Troubleshooting

Modify the program accordingly. Example: DEF Prog(a:IN) REAL a ...

Related codes

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →