KUKA Error KSS00364 — Mode selector / 27 V power supply of the PC (KPC) / CIB
InfoKUKA KSS00364 (“Mode selector / 27 V power supply of the PC (KPC) / CIB”): “Unknown operation mode”: the operating mode read by the safety section is invalid. Likely part: CIB (Cabinet Interface Board) +1 more.
Updated 2026-09-09 · LogrobotLM reference
Cause
“Unknown operation mode”: the operating mode read by the safety section is invalid. Documented case: failure of the 27 V section of the control PC that powers the mode selection path; can also come from the smartPAD or the CIB link.
Part to check / replace
KUKA KSS00364 points to the hardware below — start here before ordering.
Tap a part for every code that points to it — and verify the exact variant for your controller before ordering.
Related codes
Same hardware involved
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →