KUKA Error KSS26130 — KPP / intermediate circuit (DC link)

Info

KUKA KSS26130 (“KPP / intermediate circuit (DC link)”): “Charging of intermediate circuit failed”: precharging of the DC link does not complete. Likely part: KPP (KUKA Power Pack — supply & DC bus) +1 more.

Updated 2026-09-09 · LogrobotLM reference

Cause

“Charging of intermediate circuit failed”: precharging of the DC link does not complete. Causes: defective KPP precharge circuit, short circuit on the DC link side (KSP, ballast resistor), or insufficient mains voltage.

Part to check / replace

KUKA KSS26130 points to the hardware below — start here before ordering.

Tap a part for every code that points to it — and verify the exact variant for your controller before ordering.

Related codes

Same hardware involved

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →