ABB Error 38208 — Axis resolvers fault
ErrorABB 38208 (“Axis resolvers fault”): Excessive voltage received from an axis resolver (sum of squares exceeds the maximum permitted). Likely part: Axis resolvers (Axis resolvers).
Updated 2026-10-22 · LogrobotLM reference
What it means
Excessive voltage received from an axis resolver (sum of squares exceeds the maximum permitted).
What to check
- Check the resolver wiring of the affected axis and replace the SMB board or the axis resolver.
- Note: Equivalent to the S4 resolver electrical faults (33104).
Part to check / replace
ABB 38208 points to the hardware below — start here before ordering.
Tap a part for every code that points to it — and verify the exact variant for your controller before ordering.
Related codes
Same hardware involved
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →