ABB Error 39522 — Axis computer not found

Error

ABB 39522 (“Axis computer not found”): Axis computer not found: the axis computer of drive module 1 is not connected to the main computer. Likely part: Calculateur d'axes / Liaison Control-Drive Module (computer axis / link Control-Drive Module) +1 more.

Updated 2026-10-22 · LogrobotLM reference

What it means

Axis computer not found: the axis computer of drive module 1 is not connected to the main computer. The system goes to SYS FAIL.

What to check

  • Check that the main switch of drive module 1 is ON.
  • Check the cable between the Control Module and the Drive Module (break, poorly seated connectors).
  • On cabinets with a metal cover, firmly reseat the red-marked Ethernet link and check its other end at the axis computer (lower front right of the cabinet).
  • Check the axis computer power supply.
  • Note: Complements 32575 / 33148 (axis computer) and 39520 (loss of the drive module).

Part to check / replace

ABB 39522 points to the hardware below — start here before ordering.

Tap a part for every code that points to it — and verify the exact variant for your controller before ordering.

Related codes

Same hardware involved

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →