ABB Error 90201Limit switch open

Error / Erreur

🇫🇷 Fin de course / Limites de zone de travail

CHAÎNES DE SÉCURITÉ SUPERVISÉES & SAFETY CONTROLLER (9xxxx)

ABB 90201 (“Limit switch open”): Limit switch open — ABB robot hardware event on the controller hardware (IRC5 / Omnicore). Likely part: Fin de course / Limites de zone de travail (Fin de course / Limites de zone de travail).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Limit switch open — ABB robot hardware event on the controller hardware (IRC5 / Omnicore). Seen across controller generations. Severity: Critical. Field diagnosis below (French); your robot's own manual remains authoritative.

Limit switch open : l'interrupteur de fin de course du robot s'est ouvert — le robot a été conduit hors de la plage de travail définie par les fins de course montés sur l'axe. Le système passe en Motors OFF.

What to check · Que vérifier

  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • Ramener l'axe dans la plage en manœuvrant avec le dispositif de shunt de fin de course (procédure constructeur).
  • Vérifier le réglage mécanique des cames de fin de course.
  • Contrôler le câblage du circuit si l'ouverture ne correspond pas à une position réelle hors zone.
  • À savoir : Version « physique » du 90200 (ouvert par le Safety Controller). Fins de course optionnels selon modèle : présents surtout sur axes 1-3 des porteurs lourds.

Part to check / replace · Pièce à contrôler / remplacer

ABB 90201 points to the hardware below — start here before ordering. · 90201 met en cause l'organe ci-dessous : commencez par là.

Tap a part for every code that points to it — and verify the exact variant for your controller before ordering. · Touchez une pièce pour tous les codes qui la citent ; vérifiez la variante exacte avant commande.

Frequently asked · Questions fréquentes

What does ABB error 90201 mean?
ABB 90201 (“Limit switch open”): Limit switch open — ABB robot hardware event on the controller hardware (IRC5 / Omnicore). Seen across controller generations. Severity: Critical. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 90201?
Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault. Ramener l'axe dans la plage en manœuvrant avec le dispositif de shunt de fin de course (procédure constructeur).
Which part is involved in ABB 90201?
90201 points to Fin de course / Limites de zone de travail (Fin de course / Limites de zone de travail). Confirm the real cause against the robot backup before replacing a part.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →