ABB Error 90206 — Safety chain — General Stop fault
ErrorABB 90206 (“Safety chain — General Stop fault”): General stop open: "The general mode safeguarded space stop circuit has been broken" (exact wording of the French message recorded on an IRC5 RobotWare 6.08 cabinet). Likely part: Chaîne de sécurité — Arrêt général (General Stop) (Chaîne de sécurité — Arrêt général (General Stop)).
Updated 2026-10-22 · LogrobotLM reference
What it means
General stop open: "The general mode safeguarded space stop circuit has been broken" (exact wording of the French message recorded on an IRC5 RobotWare 6.08 cabinet). Motor power can no longer be established.
What to check
- Identify the open device on the General Stop loop (barrier, gate, button).
- Check the circuit wiring on the Panel Board / SIB and the state of the configuration jumpers.
- Check the consistency of the two redundant channels.
- Note: Correction: this code does NOT belong to the "... opened by SC" block (which starts at 90200). It is part of the hardwired safety chain group, alongside 90203 (enabling device), 90205 (automatic stop) and 90213 (dual-channel error). In the field log, it is the dominant safety event: 10 occurrences over 20 days, in bursts of 2 or 3 a few minutes apart.
Part to check / replace
ABB 90206 points to the hardware below — start here before ordering.
Tap a part for every code that points to it — and verify the exact variant for your controller before ordering.
Related codes
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →