ABB Error 90312 — Safety chain / Axis Computer / Panel Board fault
ErrorABB 90312 (“Safety chain / Axis Computer / Panel Board fault”): Enable 2 Open: the Enable 2 circuit monitoring the Axis Computer is open; the system goes to SYS HALT. Likely part: Chaîne de sécurité / Axis Computer / Panel Board (safety chain / Axis Computer / Panel Board).
Updated 2026-10-22 · LogrobotLM reference
What it means
Enable 2 Open: the Enable 2 circuit monitoring the Axis Computer is open; the system goes to SYS HALT.
What to check
- Check all connections to the Axis Computer and the safety system cables.
- Check the continuity of the Enable 2 chain and any connections from a former Multi-Move/slave configuration.
- Note: Safety chain/hardware link fault. On IRC5 controllers whose configuration has been changed, old slave cabinet wiring can cause Enable 2 to open.
Part to check / replace
ABB 90312 points to the hardware below — start here before ordering.
Tap a part for every code that points to it — and verify the exact variant for your controller before ordering.
Related codes