FANUC Alarm CVIS-344 — The cylinder calculation did not converge.
FANUC CVIS-344 (“The cylinder calculation did not converge.”): The max fit error is too small. First check: First, adjust the setting of max fit error.
Updated 2026-09-17 · LogrobotLM reference
Description
The max fit error is too small. Or there are too few laser slit points or too many noisy points.
Remedy
First, adjust the setting of max fit error. Second, adjust the setting of exposure or min laser contrast so that an appropriate laser image can be obtained. Last, adjust the laser measurement area properly.
Related codes
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →