FANUC Alarm INTP-363 — PAUSE FRAME:P3 exists on line P2-P1
Manufacturer wording — PAUSE (%s^4, %d^5) FRAME:P3 exists on line P2-P1
The manual prints placeholders; your controller fills them in with the real group, axis or number.
FANUC INTP-363 (“PAUSE FRAME:P3 exists on line P2-P1”): KAREL program error. First check: Teach P3 out of the X-axis direction.
Updated 2026-09-17 · LogrobotLM reference
Description
KAREL program error. The X-Y plane cannot be calculated in the FRAME built-in routine be P3 is located in the X-axis direction.
Remedy
Teach P3 out of the X-axis direction.
Related codes
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →