FANUC Alarm MOTN-359 — Strt-Next too close (L:…)
Manufacturer wording — Strt-Next too close (L:%d^5)
The manual prints placeholders; your controller fills them in with the real group, axis or number.
FANUC MOTN-359 (“Strt-Next too close (L:…)”): The Start and Next positions of this A motion are too close to each other. First check: Re-touch up either the taught point of the previous A motion line or the taught point of the next A motion line.
Updated 2026-09-17 · LogrobotLM reference
Description
The Start and Next positions of this A motion are too close to each other.
Remedy
Re-touch up either the taught point of the previous A motion line or the taught point of the next A motion line.
Related codes
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →