FANUC Alarm PAIN-254WARN (%s) Non-increasing cal table

Description

After the calibration table has been shifted or a new calibration table created, a nonincreasing table of flow command values is detected. Unstable flow rates encountered. Canister position change is not proportional to fluid regulator command. The canister position feedback is unstable. : Verify regulator is working properly . Verify fluid restrictor is suitable for the desired flowrates. Check proper feedback from the linear potentiometer. If this occurs as a result of a table shift, calibrate the colorvalve in which the cal table hasbecome non-increasing.

Remedy · Remède

N/A

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique.