LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free →

FANUC Alarm PALL-141 — Cycle power to increase macros

FANUC PALL-141 (“Cycle power to increase macros”): An old smaller SYSMACRO.SV file was loaded onto the controller. First check: PalletTool logic has automatically set the number of macros to the necessary size again.

Updated 2026-09-17 · LogrobotLM reference

Description

An old smaller SYSMACRO.SV file was loaded onto the controller. The number of macros was changed to fewer than what the current version of PalletTool needs.

Remedy

PalletTool logic has automatically set the number of macros to the necessary size again. But it needs a Cold start in order for the macro table size to be increased. Perform a Cold start.

Related codes