FANUC Alarm PNT1-247 — %sMin output has flow > setpoint
FANUC PNT1-247 (“%sMin output has flow > setpoint”): With a minimum control output, the flow rate was measured to be higher than the flow rate setpoint. First check: Calibrating the resin will establish a new cracking pressure (minimum control output) for a changed fluid pressure.
Updated 2026-08-29 · LogrobotLM reference
Description
With a minimum control output, the flow rate was measured to be higher than the flow rate setpoint. The resin fluid pressure might have become too high. The I/P transducer or fluid regulator might be stuck open. Or, there might be a fairly large fluid leak. Note: Accuchop automatically faults the robot and enters into Open Loop when this failure occurs.
Remedy · Remède
Calibrating the resin will establish a new cracking pressure (minimum control output) for a changed fluid pressure. Check the resin fluid regulator and I/P transducer, and replace them if necessary.
Frequently asked · Questions fréquentes
- What does FANUC alarm PNT1-247 mean?
- FANUC PNT1-247 (“%sMin output has flow > setpoint”): With a minimum control output, the flow rate was measured to be higher than the flow rate setpoint. The resin fluid pressure might have become too high. The I/P transducer or fluid regulator might be stuck open. Or, there might be a fairly large fluid leak.…
- How do you troubleshoot FANUC alarm PNT1-247?
- Calibrating the resin will establish a new cracking pressure (minimum control output) for a changed fluid pressure. Check the resin fluid regulator and I/P transducer, and replace them if necessary.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →