FANUC Alarm PNT1-394 — Exit Maintenance program is undefined
Manufacturer wording — %sExit Maintenance program is undefined
The manual prints placeholders; your controller fills them in with the real group, axis or number.
FANUC PNT1-394 (“Exit Maintenance program is undefined”): Robot maintenance out program is not taught. First check: Teach robot maintenance out program (MNTOUT.TP).
Updated 2026-09-17 · LogrobotLM reference
Description
Robot maintenance out program is not taught.
Remedy
Teach robot maintenance out program (MNTOUT.TP).
Related codes
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →