FANUC PNT1-590 (“%sCal. max. flow rate reset”): During Accuflow calibration, the expected maximum flow rate could not be reached at the maximum output. First check: Decrease the Gain modifier used for the color, if possible.
Updated 2026-08-29 · LogrobotLM reference
Description
During Accuflow calibration, the expected maximum flow rate could not be reached at the maximum output. A new maximum flow was established.
Remedy · Remède
Decrease the Gain modifier used for the color, if possible. The new maximum flow rate is shown as point 10 in the calibration table. This value can be visually checked and accepted.
Frequently asked · Questions fréquentes
- What does FANUC alarm PNT1-590 mean?
- FANUC PNT1-590 (“%sCal. max. flow rate reset”): During Accuflow calibration, the expected maximum flow rate could not be reached at the maximum output. A new maximum flow was established.
- How do you troubleshoot FANUC alarm PNT1-590?
- Decrease the Gain modifier used for the color, if possible. The new maximum flow rate is shown as point 10 in the calibration table. This value can be visually checked and accepted.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →