FANUC Alarm PNT1-592%sCal. time out at low flow

Description

Accuflow timed out trying to reach the loweset flow rate, typically 100 cc/min. Possible causes are one of the following:

Remedy · Remède

Decrease the gain modifier used for the color, if possible. Then, retry the calibration. Check and change the transducer if necessary, replace the fluid regulator, or service the surge suppression system on the fluid supply pump. The calibration timeout parameter can also be increased.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique.