LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

FANUC Alarm PNT2-166Linear Potentiometer Unstable

FANUC PNT2-166 (“Linear Potentiometer Unstable”): During Auto Calibration, the feedback from the linear potentiometer revealed large fluctuations in canister position over a short period of time. First check: Change the applicator and repair the malfunctioning linear potentiometer.

Updated 2026-08-29 · LogrobotLM reference

Description

During Auto Calibration, the feedback from the linear potentiometer revealed large fluctuations in canister position over a short period of time. If the linear potentiometer has been improperly installed or the magnet has been misaligned, it may be the cause of this alarm.

Remedy · Remède

Change the applicator and repair the malfunctioning linear potentiometer. Retry calibration with a different applicator.

Frequently asked · Questions fréquentes

What does FANUC alarm PNT2-166 mean?
FANUC PNT2-166 (“Linear Potentiometer Unstable”): During Auto Calibration, the feedback from the linear potentiometer revealed large fluctuations in canister position over a short period of time. If the linear potentiometer has been improperly installed or the magnet has been misaligned, it may be the cause of this…
How do you troubleshoot FANUC alarm PNT2-166?
Change the applicator and repair the malfunctioning linear potentiometer. Retry calibration with a different applicator.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →