FANUC Alarm PNT2-175 — (%s) Non-increasing cal table
Description
After the calibration table has been shifted or a new calibration table created, a non-increasing table of flow command values is detected. Unstable flow rates were encountered. The canister position change is not proportional to fluid regulator command. The canister position feedback is unstable.
Remedy · Remède
Verify regulator is working properly. Verify fluid restrictor is suitable for the desired flow rates. Check proper feedback from the linear potentiometer. If this occurs as a result of a table shift, calibrate the color valve in which the cal table has become non-increasing.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique.