FANUC Alarm PNT2-176 — Calculated output > Max Output

FANUC PNT2-176 (“Calculated output > Max Output”): The calculated command counts are above the Applicator Parameter Maximum Output value (1000 counts, or 8000 counts hires). First check: Determine what is limiting the flow rate.

Updated 2026-09-17 · LogrobotLM reference

Description

The calculated command counts are above the Applicator Parameter Maximum Output value (1000 counts, or 8000 counts hires). Fluid restrictor is too small or the regulator is not working properly.

Remedy

Determine what is limiting the flow rate. Check the Color Data Hi/Low flow range settings. PNT1- 256, Calculated output < min output.