FANUC Alarm PNT2-176 — Calculated output > Max Output
Description
The calculated command counts are above the Applicator Parameter Maximum Output value (1000 counts, or 8000 counts hires). Fluid restrictor is too small or the regulator is not working properly.
Remedy · Remède
Determine what is limiting the flow rate. Check the Color Data Hi/Low flow range settings. PNT1- 256, Calculated output < min output.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique.