FANUC Transducer — Transducer
🇫🇷 Transducteur · FANUC spare part — Updated 2026-08-29
FANUC Transducer — Transducer — is referenced by 30 FANUC fault codes in the LogrobotLM catalogue — including PAIN-283, PAIN-284, PAIN-420. Those are the faults that put this part under suspicion; confirm the real cause against your robot's backup before ordering a replacement.
Fault codes that point to this part · Codes qui la mettent en cause
Searching for a Transducer? These FANUC faults implicate it in their field notes. Open any one for the meaning and what to check — then confirm which cause is really yours before ordering. · Vous cherchez une Transducer ? Ces défauts FANUC la citent — ouvrez-en un pour la cause et les vérifications avant de commander.
- PAIN-283WARN %sMin. output has flow > setpoint
- PAIN-284WARN %sMax. output has flow < setpoint
- PAIN-420WARN %sMax. output has speed < setpoint
- PAIN-443WARN %sMin. output has flow > setpoint
- PAIN-444WARN %sMax. output has flow < setpoint
- PAIN-503WARN %sFlow rate avg. error excessive
- PAIN-533WARN %sFlow rate avg. error excessive
- PAIN-585PAUS %sMax output has flow < setpoint
- PAIN-586PAUS %sMin output has flow > setpoint
- PAIN-588PAUS %sMax output has feed < setpoint
- PAIN-589PAUS %sMin output has feed > setpoint
- PNT1-249%sMax output has feed < setpoint
- PNT1-250%sMin output has feed > setpoint
- PNT1-596%sMin. output has flow > setpoint
- PNT1-646%sFlow rate avg. error excessive
- PNT1-701%sMax. output has speed < setpoint
- PNT1-708%sSpeed avg. error excessive
- PNT1-718%sMax. output has speed < setpoint
- PNT1-725%sSpeed avg. error excessive
- PNT2-246%sMax output has flow < setpoint
- PNT2-247%sMin output has flow > setpoint
- PNT2-249%sMax output has feed < setpoint
- PNT2-250%sMin output has feed > setpoint
- PNT2-567%sMin. output has flow > setpoint
- PNT2-568%sMax. output has flow < setpoint
- PNT2-706%sTurbine under speed fault
- PNT2-718%sMax. output has speed < setpoint
- PNT2-722%sTurbine over speed
- PNT2-723%sTurbine under speed fault
- PNT2-724%sTurbine under speed warning
Often diagnosed together · Souvent diagnostiqués ensemble
Parts cited by the same faults as Transducer — check the whole chain before concluding. · Organes cités par les mêmes défauts que Transducer.
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →