FANUC Alarm SPOT-034 — PAUSE Backup close fault …
Manufacturer wording — PAUSE Backup close fault %s
The manual prints placeholders; your controller fills them in with the real group, axis or number.
FANUC SPOT-034 (“PAUSE Backup close fault …”): The BU Close Detect input was not received within the specified timeout period. First check: Verify the input is assigned correctly; verify the input is being made when the backup gun is closed; or if needed, increase the timeout value (in $spoteqsetup.$bu_cl_to).
Updated 2026-09-17 · LogrobotLM reference
Description
The BU Close Detect input was not received within the specified timeout period.
Remedy
Verify the input is assigned correctly; verify the input is being made when the backup gun is closed; or if needed, increase the timeout value (in $spoteqsetup.$bu_cl_to).
Related codes