FANUC SPOT-034 (“PAUSE Backup close fault …”): The BU Close Detect input was not received within the specified timeout period. First check: Verify the input is assigned correctly; verify the input is being made when the backup gun is closed; or if needed, increase the timeout value (in $spoteqsetup.$bu_cl_to).

Updated 2026-09-17 · LogrobotLM reference

Description

The BU Close Detect input was not received within the specified timeout period.

Remedy

Verify the input is assigned correctly; verify the input is being made when the backup gun is closed; or if needed, increase the timeout value (in $spoteqsetup.$bu_cl_to).