FANUC Alarm SRVO-230 — SERVO Chain 1 (+24v) abnormal
Error- Hardware
- emergency stop and dual safety chains
- Controllers
- R-J3iB / R-30iA / R-30iB
- FANUC class
- SERVO
- Hardware family
- FANUC emergency stop, pendant and dual safety chain alarms
FANUC SRVO-230 (“SERVO Chain 1 (+24v) abnormal”): A single chain 1 (+24V) failure occurred. First check: 1. Repair the circuit of the chain 1 (+24V) on the hardware.
Updated 2026-10-22 · LogrobotLM reference
Description
A single chain 1 (+24V) failure occurred.
Remedy
1. Repair the circuit of the chain 1 (+24V) on the hardware. 2. Set CHAIN FAILURE detection to TRUE on the SYSTEM/CONFIG screen. 3. Press RESET on the teach pendant.
Field diagnosis
Fault detected on chain 1 of the dual emergency stop circuit. At power-up, a teach pendant of a different specification (RIA/CE versus standard) gives the same code.
What to check
- Check the alarm history: if the code accompanies an operator panel, teach pendant or deadman switch stop, repeat the action (press, then release fully); the appearance of SRVO-236 confirms the chain has been restored, then reset.
- Otherwise check the teach pendant specification, then the devices wired on both channels.
- Note: Never reset a chain without understanding which channel dropped out: with one dead channel, the emergency stop is no longer redundant.
- Diagnostic sequence “Dual emergency stop circuit”: A chain code (230/231, 266…275, 370…373) means that only one of the two redundant channels has switched: the robot still runs, but safety is no longer redundant. Identify the channel from the number (1 = +24 V, 2 = 0 V), reproduce a firm operation of the device concerned, wait for the chain-repaired message, then RES_1CH and RESET. Never reset without having found the cause.
Related codes
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →