FANUC Alarm SRVO-105 — SERVO Door open or E.Stop
Error- Hardware
- emergency stop and dual safety chains
- Controllers
- R-J3iB / R-30iA / R-30iB
- FANUC class
- SERVO
- Hardware family
- FANUC emergency stop, pendant and dual safety chain alarms
FANUC SRVO-105 (“SERVO Door open or E.Stop”): The controller door has been opened, emergency stop signals have been detected for a short time, or a hardware connection has been mis-wired. First check: Close controller door and press RESET.
Updated 2026-10-22 · LogrobotLM reference
Description
The controller door has been opened, emergency stop signals have been detected for a short time, or a hardware connection has been mis-wired.
Remedy
Close controller door and press RESET. If the reset is not effective, correct the hardware connection.
Field diagnosis
Cabinet door detected open, or a transient emergency stop signal; a teach pendant of a different specification from the cabinet (RIA/CE versus standard) causes the same code.
What to check
- Close the cabinet door (and the auxiliary cabinet door, if present), then reset.
- Check the door switch and its wiring.
- Verify that the connected teach pendant matches the safety specification of the controller.
- Note: A teach pendant borrowed from another line is a classic cause of SRVO-105 appearing at power-up.
Related codes