LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free →

FANUC Alarm SVGN-150 — Synchronization enable is required.

FANUC SVGN-150 (“Synchronization enable is required.”): The linear distance function is enabled, but synchronize move to pressure is not enabled. First check: Enable synchronize move to pressure position (set $sgsyscfg.$sync_mv2prs=TRUE) OR disable linear distance (set $sgsyscfg.$lin_dst_enb=FALSE).

Updated 2026-09-17 · LogrobotLM reference

Description

The linear distance function is enabled, but synchronize move to pressure is not enabled.

Remedy

Enable synchronize move to pressure position (set $sgsyscfg.$sync_mv2prs=TRUE) OR disable linear distance (set $sgsyscfg.$lin_dst_enb=FALSE).

Related codes

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →