FANUC Alarm SVGN-153 — Invalid increase signal(Robot).
FANUC SVGN-153 (“Invalid increase signal(Robot).”): The Digital Output assigned to notify of increased error on the Robot Tip is invalid. First check: Check the present value of $sggun#.$setup.$rbtincioidx (on the system variable screen).
Updated 2026-09-17 · LogrobotLM reference
Description
The Digital Output assigned to notify of increased error on the Robot Tip is invalid.
Remedy
Check the present value of $sggun#.$setup.$rbtincioidx (on the system variable screen). Change this value to the number of a DO that is configured and unused. Check the Digital Output list (I/O-Type-DIGITAL-OUTPUTS) to find an available DO point to use.
Related codes
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →