FANUC Alarm SVGN-160 — Invalid calibration point: bad torque.
FANUC SVGN-160 (“Invalid calibration point: bad torque.”): A pressure calibration point has a torque value that is not greater than 0.0, or is not in ascending order. First check: Perform Pressure Calibration again.
Updated 2026-08-29 · LogrobotLM reference
Description
A pressure calibration point has a torque value that is not greater than 0.0, or is not in ascending order.
Remedy · Remède
Perform Pressure Calibration again. Make sure that both torque and pressure increase at each successive calibration point.
Frequently asked · Questions fréquentes
- What does FANUC alarm SVGN-160 mean?
- FANUC SVGN-160 (“Invalid calibration point: bad torque.”): A pressure calibration point has a torque value that is not greater than 0.0, or is not in ascending order.
- How do you troubleshoot FANUC alarm SVGN-160?
- Perform Pressure Calibration again. Make sure that both torque and pressure increase at each successive calibration point.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →