LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free →

FANUC Alarm TMAT-015 — G:… does not support TorchMate

Manufacturer wording — G:%s does not support TorchMate
The manual prints placeholders; your controller fills them in with the real group, axis or number.

FANUC TMAT-015 (“G:… does not support TorchMate”): TorchMate mastering or TorchMate adjustment was used on a motion group that is not associated with the robot(s) in your system. First check: REMEDY1: Select for jogging a motion group that is associated with the robot(s) in your system.

Updated 2026-09-17 · LogrobotLM reference

Description

TorchMate mastering or TorchMate adjustment was used on a motion group that is not associated with the robot(s) in your system. CAUSE 1: At mastering, the group is determined by the currently selected jog motion group as shown in the TP status line. You have selected for jogging a motion group associated to a positioner, nobot, or index device. CAUSE 2: TorchMate adjustment has macros for each robot group installed on your system. The currently executing program includes a TorchMate macro and does not include that correct robot motion group, or it does not contain a robot motion group at all.

Remedy

REMEDY1: Select for jogging a motion group that is associated with the robot(s) in your system. REMEDY 2: Correct the programming error.

Related codes

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →