KUKA Error KSS15101 — SIB safe inputs / X11 wiring
InfoKUKA KSS15101 (“SIB safe inputs / X11 wiring”): “Error at safety device input”: a safety peripheral input is inconsistent — the two channels of a dual-channel input do not switch together (incomplete X11 wiring, worn contact, SIB fuse, smartPAD cable). Likely part: SIB (Safety Interface Board) +1 more.
Updated 2026-09-09 · LogrobotLM reference
Cause
“Error at safety device input”: a safety peripheral input is inconsistent — the two channels of a dual-channel input do not switch together (incomplete X11 wiring, worn contact, SIB fuse, smartPAD cable).
Part to check / replace
KUKA KSS15101 points to the hardware below — start here before ordering.
Tap a part for every code that points to it — and verify the exact variant for your controller before ordering.
Related codes
Same hardware involved
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →