Manufacturer wording — PAUS %sMax output has flow < setpoint
The manual prints placeholders; your controller fills them in with the real group, axis or number.

FANUC PAIN-585 (“PAUS …Max output has flow < setpoint”): With a maximum control output, the flow rate was measured to be lower than the setpoint (requested flow). First check: Check the gun tip and the whole gun for clogging. Likely part: Transducer (Transducer).

Updated 2026-09-17 · LogrobotLM reference

Description

With a maximum control output, the flow rate was measured to be lower than the setpoint (requested flow). The resin gun may be clogging. The resin or pilot air line may be pinched. The resin fluid press.

Remedy

Check the gun tip and the whole gun for clogging. Check the resin lines for pinching, especially at places where they flex. Check the resin supply pressure. Check and replace if necessary the I/P transducer.

Part to check / replace

FANUC PAIN-585 points to the hardware below — start here before ordering.

Tap a part for every code that points to it — and verify the exact variant for your controller before ordering.