FANUC Alarm PAIN-585 — PAUS %sMax output has flow < setpoint
FANUC PAIN-585 (“PAUS %sMax output has flow < setpoint”): With a maximum control output, the flow rate was measured to be lower than the setpoint (requested flow). First check: Check the gun tip and the whole gun for clogging. Likely part: Transducer (Transducer).
Updated 2026-08-29 · LogrobotLM reference
Description
With a maximum control output, the flow rate was measured to be lower than the setpoint (requested flow). The resin gun may be clogging. The resin or pilot air line may be pinched. The resin fluid press.
Remedy · Remède
Check the gun tip and the whole gun for clogging. Check the resin lines for pinching, especially at places where they flex. Check the resin supply pressure. Check and replace if necessary the I/P transducer.
Part to check / replace · Pièce à contrôler / remplacer
FANUC PAIN-585 points to the hardware below — start here before ordering. · PAIN-585 met en cause l'organe ci-dessous : commencez par là.
Tap a part for every code that points to it — and verify the exact variant for your controller before ordering. · Touchez une pièce pour tous les codes qui la citent ; vérifiez la variante exacte avant commande.
Frequently asked · Questions fréquentes
- What does FANUC alarm PAIN-585 mean?
- FANUC PAIN-585 (“PAUS %sMax output has flow < setpoint”): With a maximum control output, the flow rate was measured to be lower than the setpoint (requested flow). The resin gun may be clogging. The resin or pilot air line may be pinched. The resin fluid press.
- How do you troubleshoot FANUC alarm PAIN-585?
- Check the gun tip and the whole gun for clogging. Check the resin lines for pinching, especially at places where they flex. Check the resin supply pressure. Check and replace if necessary the I/P transducer.
- Which part is involved in FANUC PAIN-585?
- PAIN-585 points to Transducer (Transducer). Confirm the real cause against the robot backup before replacing a part.
Related codes / Codes liés
Same hardware involved / Même matériel en cause
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →