FANUC Alarm PNT1-250 — Min output has feed > setpoint
Manufacturer wording — %sMin output has feed > setpoint
The manual prints placeholders; your controller fills them in with the real group, axis or number.
FANUC PNT1-250 (“Min output has feed > setpoint”): With a minimum control output, the glass feed rate was measured to be higher than the feed rate setpoint. First check: Calibrating the glass will establish a new cracking pressure (minimum control output). Likely part: Transducer (Transducer).
Updated 2026-09-17 · LogrobotLM reference
Description
With a minimum control output, the glass feed rate was measured to be higher than the feed rate setpoint. The motor (glass) RPM might have become too high. The I/P transducer might be stuck open. Note: Accuchop automatically faults the robot and enters into Open Loop when this failure occurs.
Remedy
Calibrating the glass will establish a new cracking pressure (minimum control output). Check and replace the I/P transducer, if necessary.
Part to check / replace
FANUC PNT1-250 points to the hardware below — start here before ordering.
Tap a part for every code that points to it — and verify the exact variant for your controller before ordering.
Related codes
Same hardware involved