FANUC Alarm PNT1-561 — Cal. max. flow rate reset

Manufacturer wording — %sCal. max. flow rate reset
The manual prints placeholders; your controller fills them in with the real group, axis or number.

FANUC PNT1-561 (“Cal. max. flow rate reset”): During Accuflow calibration, the expected maximum flow rate could not be reached at the maximum output. First check: Try decreasing the Gain modifier used for the color.

Updated 2026-09-17 · LogrobotLM reference

Description

During Accuflow calibration, the expected maximum flow rate could not be reached at the maximum output. A new maximum flow was established.

Remedy

Try decreasing the Gain modifier used for the color. The new maximum flow rate is shown as point 10 in the calibration table. This value can be visually checked and accepted.