FANUC Alarm PNT1-575 — %s0 fluid flow rate timeout
Description
All of the conditions were set for fluid to be flowing and a zero flow rate was measured for longer than the Zero flow timeout parameter. This might be caused by one of the following:
Remedy · Remède
Check that the gun is triggering properly. If you observe fluid to be flowing, check and possibly replace the fluid flow meter. Icrease the Zero flow timeout parameter (by about 25%), if possible.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique.