FANUC Alarm PNT1-575 — 0 fluid flow rate timeout

Manufacturer wording — %s0 fluid flow rate timeout
The manual prints placeholders; your controller fills them in with the real group, axis or number.

FANUC PNT1-575 (“0 fluid flow rate timeout”): All of the conditions were set for fluid to be flowing and a zero flow rate was measured for longer than the Zero flow timeout parameter. First check: Check that the gun is triggering properly. Likely part: Fluid flow meter (Fluid flow meter).

Updated 2026-09-17 · LogrobotLM reference

Description

All of the conditions were set for fluid to be flowing and a zero flow rate was measured for longer than the Zero flow timeout parameter. This might be caused by one of the following:

Remedy

Check that the gun is triggering properly. If you observe fluid to be flowing, check and possibly replace the fluid flow meter. Icrease the Zero flow timeout parameter (by about 25%), if possible.

Part to check / replace

FANUC PNT1-575 points to the hardware below — start here before ordering.

Tap a part for every code that points to it — and verify the exact variant for your controller before ordering.

Related codes

Same hardware involved