FANUC Alarm PNT2-250 — Min output has feed > setpoint

Manufacturer wording — %sMin output has feed > setpoint
The manual prints placeholders; your controller fills them in with the real group, axis or number.

FANUC PNT2-250 (“Min output has feed > setpoint”): With a minimum control output, the glass feed rate was measured to be higher than the feed rate setpoint. First check: Calibrating the glass will establish a new cracking pressure (minimum control output). Likely part: Transducer (Transducer).

Updated 2026-09-17 · LogrobotLM reference

Description

With a minimum control output, the glass feed rate was measured to be higher than the feed rate setpoint. The motor (glass) RPM might have become too high. The I/P transducer might be stuck open. Note: Accuchop automatically faults the robot and enters into Open Loop when this failure occurs.

Remedy

Calibrating the glass will establish a new cracking pressure (minimum control output). Check and replace the I/P transducer if necessary.

Part to check / replace

FANUC PNT2-250 points to the hardware below — start here before ordering.