FANUC Alarm PNT2-604 — 0 fluid flow rate timeout

Manufacturer wording — %s0 fluid flow rate timeout
The manual prints placeholders; your controller fills them in with the real group, axis or number.

FANUC PNT2-604 (“0 fluid flow rate timeout”): All of the conditions were set for fluid to be flowing and a zero flow rate was measured for longer than the Zero flow timeout parameter. First check: Check that the gun is properly triggering. Likely part: Fluid flow meter (Fluid flow meter).

Updated 2026-09-17 · LogrobotLM reference

Description

All of the conditions were set for fluid to be flowing and a zero flow rate was measured for longer than the Zero flow timeout parameter. This may be caused by: a broken applicator trigger, a loss of fluid supply pressure, a broken fluid flow meter, a broken cable (to the flow meter), or a Zero flow timeout value that is too short. Note, AccuFlow temporarily automatically changes to Open Loop when this alarm occurs.

Remedy

Check that the gun is properly triggering. If fluid was observed to be flowing, check and possibly replace the fluid flow meter. Possibly increase the Zero flow timeout parameter (by about 25%).

Part to check / replace

FANUC PNT2-604 points to the hardware below — start here before ordering.

Tap a part for every code that points to it — and verify the exact variant for your controller before ordering.