FANUC Alarm SRVO-009 — SERVO Pneumatic pressure alarm

Error
Hardware
robot signals and connection cable
Controllers
R-J3iB / R-30iA / R-30iB
FANUC class
SERVO

FANUC SRVO-009 (“SERVO Pneumatic pressure alarm”): The pneumatic pressure alarm indicates the presence of a defect. First check: If the pneumatic pressure alarm is not detected, check the cable.

Updated 2026-10-22 · LogrobotLM reference

Description

The pneumatic pressure alarm indicates the presence of a defect. If the pneumatic pressure alarm is not detected, however, the most likely is the PPABN signal of a robot connection cable being at the 0 V level.

Remedy

If the pneumatic pressure alarm is not detected, check the cable.

Field diagnosis

Air pressure fault reported, or the PPABN signal in the robot connection cable is at 0 V although the pressure is normal.

What to check

  • Restore the pressure; otherwise check the end-effector connector and the robot connection cable (ground fault, wire break).
  • If no pressure switch is fitted, disable the monitoring in the system configuration.
  • Note: After a tool change, a pressure switch that has not been rewired is the most frequent cause.