LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free →

FANUC Alarm SRVO-005 — SERVO Robot overtravel

Error
Hardware
emergency stop and dual safety chains
Controllers
R-J3iB / R-30iA / R-30iB
FANUC class
SERVO

FANUC SRVO-005 (“SERVO Robot overtravel”): The robot has moved beyond a hardware limit switch on the axes. First check: 1. Select [System OT release] on the overtravel release screen to release each robot axis from the overtravel state.

Updated 2026-10-22 · LogrobotLM reference

Description

The robot has moved beyond a hardware limit switch on the axes. It is factory-placed in the overtravel state for packing purposes.

Remedy

1. Select [System OT release] on the overtravel release screen to release each robot axis from the overtravel state. 2. Press the SHIFT key, and press the alarm release button to reset the alarm condition. 3. Continuously press the SHIFT key, and jog the robot to bring all axes into the movable range. 4. Check the FS2 fuse on the servo amplifier.

Field diagnosis

An axis has reached its electrical limit switch. On delivery, robots are deliberately left in the overtravel condition for shipping.

What to check

  • On the overtravel release screen, select the system release, then reset while holding SHIFT; still holding SHIFT, jog each axis back within its stroke.
  • Jogging is blocked in the overtravel direction while the alarm is active.
  • Note: On models without a physical limit switch, this code rather points to an RDI cable or an input at 0 V.