FANUC Alarm SRVO-136SERVO DCLVAL alarm (G:%d A:%d)

Description

The back-up charge circuit for the amplifier has trouble.

Remedy · Remède

Check the cables and connections between the amplifier (CN1) and the MCC. Check the fuse (F1,F3) in the transformer. If using a B-cabinet, replace the EMG control printed circuit board. Replace the amplifier.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique.