FANUC Alarm SRVO-205 — SYSTEM Fence open(SVEMG abnormal)
Error- Hardware
- emergency stop and dual safety chains
- Controllers
- R-J3iB / R-30iA / R-30iB
- FANUC class
- SYSTEM
- Hardware family
- FANUC emergency stop, pendant and dual safety chain alarms
FANUC SRVO-205 (“SYSTEM Fence open(SVEMG abnormal)”): The fence circuit is open and mis-wiring on SVEMG is detected. First check: Power off. Correct the wiring on SVEMG.
Updated 2026-10-22 · LogrobotLM reference
Description
The fence circuit is open and mis-wiring on SVEMG is detected.
Remedy
Power off. Correct the wiring on SVEMG. Close the fence circuit and then press RESET. Refer to the maintenance manual for details.
Field diagnosis
The fence circuit was opened without the emergency stop line being cut: one of the two EAS channels does not follow the other.
What to check
- Check the switches and cables of both EAS channels; replace any suspect cable.
- Otherwise, the emergency stop board is suspect (full backup before replacement).
- A power cycle is required to clear the code.
- Note: Doors with a single contact wired to both channels in parallel are the leading cause.
Related codes
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →