FANUC Alarm SRVO-264 — SYSTEM E.STOP circuit abnormal 1
Error- Hardware
- emergency stop and dual safety chains
- Controllers
- R-J3iB / R-30iA
- FANUC class
- SYSTEM
- Hardware family
- FANUC emergency stop, pendant and dual safety chain alarms
FANUC SRVO-264 (“SYSTEM E.STOP circuit abnormal 1”): MON3 status is ON when servo is ready The status of MON3 is abnormal First check: Repair the circuit of MON3 on E.STOP unit
Updated 2026-10-22 · LogrobotLM reference
Description
MON3 status is ON when servo is ready The status of MON3 is abnormal
Remedy
Repair the circuit of MON3 on E.STOP unit
Field diagnosis
The emergency stop unit is faulty: loose connector or failed internal circuit.
What to check
- Reseat all connectors of the emergency stop unit, then replace the unit if the code returns.
- A power cycle is required to clear.
- Note: Tends to appear after work inside the cabinet: a connector that was not properly reseated.
Related codes
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →