FANUC Alarm SRVO-265 — SERVO E.STOP circuit abnormal 2
Error- Hardware
- emergency stop and dual safety chains
- Controllers
- R-J3iB / R-30iA
- FANUC class
- SERVO
- Hardware family
- FANUC emergency stop, pendant and dual safety chain alarms
FANUC SRVO-265 (“SERVO E.STOP circuit abnormal 2”): FENCE1 status is still ON when FENCE signal is asserted First check: Repair the circuit of FENCE1
Updated 2026-10-22 · LogrobotLM reference
Description
FENCE1 status is still ON when FENCE signal is asserted
Remedy
Repair the circuit of FENCE1
Field diagnosis
Second level of emergency stop unit fault: its internal circuitry is faulty.
What to check
- Replace the emergency stop unit; while doing so, check the connectors to the servo amplifier and to the operator panel.
- Note: The code does not clear without a power cycle.
Related codes
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →