FANUC Alarm SRVO-275 — SERVO NTED2 status abnormal
Error- Hardware
- emergency stop and dual safety chains
- Controllers
- R-J3iB / R-30iA / R-30iB
- FANUC class
- SERVO
- Hardware family
- FANUC emergency stop, pendant and dual safety chain alarms
FANUC SRVO-275 (“SERVO NTED2 status abnormal”): T2 mode is not permited to move robot First check: Change mode switch to T1 ot AUTO
Updated 2026-10-22 · LogrobotLM reference
Description
T2 mode is not permited to move robot
Remedy
Change mode switch to T1 ot AUTO
Field diagnosis
Chain alarm on channel 2 of the deadman switch signal.
What to check
- Same procedure as SRVO-274: deadman switch released then firmly gripped again, NTED circuit, teach pendant, cable.
- Release with RES_1CH, then RESET.
- Note: Both channels faulted simultaneously: teach pendant or cable, not the operator.
Related codes
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →