FANUC Alarm SRVO-275 — SERVO NTED2 status abnormal

Error
Hardware
emergency stop and dual safety chains
Controllers
R-J3iB / R-30iA / R-30iB
FANUC class
SERVO

FANUC SRVO-275 (“SERVO NTED2 status abnormal”): T2 mode is not permited to move robot First check: Change mode switch to T1 ot AUTO

Updated 2026-10-22 · LogrobotLM reference

Description

T2 mode is not permited to move robot

Remedy

Change mode switch to T1 ot AUTO

Field diagnosis

Chain alarm on channel 2 of the deadman switch signal.

What to check

  • Same procedure as SRVO-274: deadman switch released then firmly gripped again, NTED circuit, teach pendant, cable.
  • Release with RES_1CH, then RESET.
  • Note: Both channels faulted simultaneously: teach pendant or cable, not the operator.