FANUC Alarm SRVO-206 — SYSTEM Deadman switch (SVEMG abnormal)
Error- Hardware
- emergency stop and dual safety chains
- Controllers
- R-J3iB / R-30iA / R-30iB
- FANUC class
- SYSTEM
- Hardware family
- FANUC emergency stop, pendant and dual safety chain alarms
FANUC SRVO-206 (“SYSTEM Deadman switch (SVEMG abnormal)”): The teach pendant deadman switch is released while the teach pendant is enabled. First check: Power off. Correct the wiring on SVEMG Power on.
Updated 2026-10-22 · LogrobotLM reference
Description
The teach pendant deadman switch is released while the teach pendant is enabled. And miswiring on SVEMG is detected.
Remedy
Power off. Correct the wiring on SVEMG Power on. Press the teach pendant deadman switch. Press RESET. Refer to the maintenance manual for details.
Field diagnosis
With the teach pendant enabled, the deadman switch was released (or squeezed fully) without the emergency stop line opening.
What to check
- Replace the teach pendant first, then the teach pendant cable.
- If the fault persists, the main board or the emergency stop board is at fault (full backup before replacement).
- Power cycle to clear.
- Note: A damp teach pendant, or one whose deadman switch has taken a knock, gives this code rather than SRVO-003.
Related codes
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →