LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free →

FANUC Alarm SRVO-349 — DCS MCC ON alarm …,…

Error
Hardware
main contactor (MCC)
Controllers
R-30iA / R-30iB
FANUC class
SERVO

Manufacturer wording — DCS MCC ON alarm %x,%x
The manual prints placeholders; your controller fills them in with the real group, axis or number.

FANUC SRVO-349 (“DCS MCC ON alarm …,…”): A command was issued to turn on the magnetic contactor, but the magnetic contactor was not turned on. First check: 1. Replace the E-stop unit. Likely part: Servo amplifier (Servo amplifier) +2 more.

Updated 2026-10-22 · LogrobotLM reference

Description

A command was issued to turn on the magnetic contactor, but the magnetic contactor was not turned on.

Remedy

1. Replace the E-stop unit. 2. Replace the panel board. 3. Replace the servo amplifier.

Field diagnosis

Close command sent to the main contactor, with no closed feedback.

What to check

  • Replace the emergency stop unit (contactor included); then the panel board (R-30iA) or the main board after backup (R-30iB); finally the amplifier.
  • Note: Contactor coil or its fuse: listen for the contactor clicking when power is applied.

Part to check / replace

FANUC SRVO-349 points to the hardware below — start here before ordering.

Tap a part for every code that points to it — and verify the exact variant for your controller before ordering.

Related codes

Same hardware involved

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →